ECN STD-0002 June 26, 2003
S-102A
The DIP switch positions 1-5 set the S-102A unit number for serial communications.
The revised switch settings are shown in to Table 1.
Set switches 1 through 5 to 0 (off) when using the S-102AR Remote Control Panel.
| Dip Switch Position | S-102A Unit Number | ||||
| 5 | 4 | 3 | 2 | 1 | |
| 0 | 0 | 0 | 0 | 0 | For S-102AR Remote Control Use |
| 0 | 0 | 0 | 0 | 1 | 1 |
| 0 | 0 | 0 | 1 | 0 | 2 |
| 0 | 0 | 0 | 1 | 1 | 3 |
| 0 | 0 | 1 | 0 | 0 | 4 |
| 0 | 0 | 1 | 0 | 1 | 5 |
| 0 | 0 | 1 | 1 | 0 | 6 |
| 0 | 0 | 1 | 1 | 1 | 7 |
| 0 | 1 | 0 | 0 | 0 | 8 |
| 0 | 1 | 0 | 0 | 1 | 9 |
| 0 | 1 | 0 | 1 | 0 | 10 |
| 0 | 1 | 0 | 1 | 1 | 11 |
| 0 | 1 | 1 | 0 | 0 | 12 |
| 0 | 1 | 1 | 0 | 1 | 13 |
| 0 | 1 | 1 | 1 | 0 | 14 |
| 0 | 1 | 1 | 1 | 1 | 15 |
| 1 | 0 | 0 | 0 | 0 | 16 |